EarthX requires we install an automatic over-voltage protection (crowbar) for alternator type charging systems. According to EarthX, "In the event of a charging system failure where the voltage increases to above 15.5V, the resistance to charging current increases, and above 16V the charging current is completely blocked. The time delay for this feature is 1 second to allow the aircraft alternat…